SPECIFICATION CONTROL DRAWING 9530A1317 Date: 04-26-00 CHEMINAX 95 OHM, AWG 30, 7 STRANDS OF AWG 38, COAXIAL CABLE Revision: A THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS Deiat RE NOMINAL VALUES IN INCHES UNLESS OTHERWISE CHARACTERISTIC IMPEDANCE 65 S ohms, Method B CONDUCTOR CAPACITANCE 13.5 pF/ft. (nominal) at 1 kHz AWG 30, 7 Strands of .0127-_ AWG 38, Tin-Coated Copper Covered Steel | yer ociTy OF PROPAGATION 79% (nominal) DIELECTRIC .080 > Rayfoam L ADDITIONAL REQUIREMENTS Coior - Natural ELECTRICAL CONDUCTOR RESISTANCE 255. ohms/1000 ft. (nominal) SHIELD INSULATION RESISTANCE 10,000 megohms (minimum) for 1000 ft. 097 +P , AWG 38, JACKET FLAWS Tin-Coated Copper SPARK TEST 1.0 kV (rms) IMPULSE TEST 6.0 kV (peak) VOLTAGE WITHSTAND 1000 volts (rms), (minimum) (DIELECTRIC) ENVIRONMENTAL FLAMMABILITY Method C HEAT SHOCK 225C LOW TEMPERATURE- ~55C/3.25 inch mandrel COLD BEND VOLTAGE WITHSTAND 1000 voits (rms), 1 minute (POST ENVIRONMENTAL) 117 - JACKET Thermorad $ PHYSICAL INSULATION (DIELECTRIC) ELONGATION 50% (minimum) TENSILE STRENGTH 800 Ibf/in? (minimum) JACKET ELONGATION 250% (minimum) TENSILE STRENGTH 2000 Ibf/in? (minimum) JACKET THICKNESS -010 inch (nominal) SHIELD COVERAGE 90% (minimum) Outer jacket color will be black, designated by a "0" appended to *he partnumber (e.g., 9530A1317-0), unless otherwise specified. WEIGHT 8.2 Ibs/1000 ft. (nominal) Designate outer jacket color with a dash number in accordance with MIL-STD-681. Raychem THIS SPECIFICATION SHEET TAKES PRECEDENCE Raychem 300 Constitution Drive OVER DOCUMENTS REFERENCED HEREIN. Menlo Park, California 94025 REFERENCE DOCUMENTS SHALL BE OF THE ISSUE 1-800-2 Raychem FAX: 1-650-361-6297 IN EFFECT ON DATE OF INVITATION FOR BID.